Skip to main content
Cisco SD-WAN
Support
Product Documentation
Viptela Documentation

Release Notes for XE SD-WAN Release 16.9.1 and SD-WAN Release 18.3

These release notes accompany the IOS XE SD-WAN Software Release 16.9.1 which provides SD-WAN capabilities for Cisco IOS XE routers and the compatible SD-WAN Software Release 18.3 for Viptela controller devices—including vSmart controllers, vBond orchestrators, and vManage NMSs—and vEdge routers.

IOS XE SD-WAN Software Release 16.9.1 and SD-WAN Software Release 18.3
July 17, 2018
Revision 1

Product Features

Below are the main product features in IOS XE SD-WAN Software Release 16.9.1 and SD-WAN Software Release 18.3:

  • Cisco IOS XE routers—The XE SD-WAN software runs on the following Cisco IOS XE routers:
    • Cisco ASR 1000 series aggregation services routers:
      • ASR 1001-HX and ASR 1001-X
      • ASR 1002-HX and ASR 1002-X
    • Cisco ISR 1000 series integrated services routers:
      • C1111-8P, C1111-8P LTE EA, and C1111-8P LTE LA
      • C1117-4P LTE EA and C1117-4P LTE LA
    • Cisco 4000 series integrated services routers:
      • ISR 4221
      • ISR 4321
      • ISR 4331
      • ISR 4351
    • ENCS 5412 with T1/E1 and 4G NIM modules
      • ISRv

    These routers support all SD-WAN software features except the following:

    • Cloud Express service
    • Cloud onRamp service
    • Standard IPsec with IKE version 1 or IKE version 2 for service-side connections
    • IPsec/GRE cloud proxy
    • IPv6 on transport connections
    • NAT pools on service-side connections
    • Reverse proxy

    See Software Installation for Cisco IOS XE Routers.

    • Email notifications of alarms—You can configure the vManage server to send email notifications to an email address or to a webhook URL when selected alarms are generated. See Configure Email Notifications for Alarms and Alarms.
    • Single sign-on (SSO)—You can enable single sign-on for the vManage NMS to allow users to be authenticated using an external identity provider. This feature complies with the SAML Version 2.0 standard. See Settings.
    • VRRP virtual MAC addresses—VRRP complies with RFC 5798 with regards to virtual MAC addresses and gratuitous ARP requests. See Configuring VRRP.

Command Changes

New and Modified Configuration Commands

Command

Hierarchy

New

Modified

Comments

log-translations vpn interface nat X    
natpool vpn interface nat X    
rewrite-rule policy    X Add layer-2-cos command.
static vpn interface nat   X  
tloc-extension-gre-from sdwan interface tunnel-interface X   On IOS XE routers.
tloc-extension-gre-to sdwan interface tunnel-interface X   On IOS XE routers.

New and Modified Operational Commands

Command New Modified Comments
show sdwan X   On IOS XE routers.
show sdwan policy X   On IOS XE routers.

New and Modified vManage Screens

Field

Screen

New

Modified

Comments

Controller Version Maintenance ► Software Repository X    
DSL PPPoA configuration Configuration ► Templates ► Feature X   For Cisco IOS XE routers.
DSL PPPoE configuration Configuration ► Templates ► Feature X   For Cisco IOS XE routers.
Multilink configuration Configuration ► Templates ► Feature X   For Cisco IOS XE routers.
SVI configuration Configuration ► Templates ► Feature X   For Cisco IOS XE routers.
Switch Port configuration Configuration ► Templates ► Feature X   For Cisco IOS XE routers.

Upgrade to SD-WAN Software Release 18.3

For details on upgrading the Viptela software, see Software Installation and Upgrade for vEdge Routers.

Note: You cannot install a Release 17.2 or earlier image on a vEdge router that is running Release 18.2.0 or later. This is the result of security enhancements implemented in Release 18.2.0. Note that if a Release 17.2 or earlier image is already present on the router, you can activate it.

To upgrade your vEdge router to SD-WAN Software Release 18.3:

  1. In vManage NMS, select the Maintenance ► Software Upgrade screen.
  2. Upgrade the controller devices to Release 18.3 in the following order:
    1. First, upgrade the vManage NMSs in the overlay network.
    2. Then, upgrade the vBond orchestrators.
    3. Next, upgrade the vSmart controllers.
  3. Select the Monitor ► Network screen.
  4. Select the devices you just upgraded, click the Control Connections tab, and verify that control connections have been established.
  5. Select the Maintenance ► Software Upgrade screen, and upgrade the vEdge routers.

Upgrade from Release 16.2 and Earlier Software Releases

Because of software changes in Release 16.3, you must modify the router configuration as follows before you upgrade from Release 16.2 or earlier to Release 18.3:

  • You can no longer configure RED drops on low-latency queuing (LLQ; queue 0). That is, if you include the policy qos-scheduler scheduling llq command in the configuration, you cannot configure drops red-drop in the same QoS scheduler. If your vEdge router has this configuration, remove it before upgrading to Release 17.2. If you do not remove the RED drop configuration, the configuration process (confd) will fail after you perform the software upgrade, and the Viptela devices will roll back to their previous configuration.
  • For vEdge 2000 routers, you can no longer configure interfaces that are not present in the router. That is, the interface names in the configuration must match the type of PIM installed in the router. For example, if the PIM module in slot 1 is a 10-Gigabit Ethernet PIM, the configuration must refer to the proper interface name, for example,10ge1/0, and not ge1/0. If the interface name does not match the PIM type, the software upgrade will fail. Before you upgrade from Release 16.2 or earlier to Release 17.2, ensure that the interface names in the router configurations are correct.

Caveats

Hardware Caveats

The following are known behaviors of the hardware:

  • The maximum aggregated throughput recommended for the ISR 1000 series routers is 100Mbps.
  • On vEdge 1000 routers, support for USB controllers is disabled by default. To attach an LTE USB dongle to a vEdge 1000 router, first attach the dongle, and then enable support for USB controllers on the vEdge router, by adding the system usb-controller command to the configuration. When you enter this command in the configuration, the router immediately reboots. Then, when the router comes back up, continue with the router configuration. Also for vEdge 1000 routers, if you plug in an LTE USB dongle after you have enabled the USB controller, or if you hot swap an LTE USB dongle after you have enabled the USB controller, you must reboot the router in order for the USB dongle to be recognized. For information about enabling the USB controller, see USB Dongle for Cellular Connection.
  • For vEdge 2000 routers, if you change the PIM type from a 1-Gigabit Ethernet to a 10-Gigabit Ethernet PIM, or vice versa, possibly as part of an RMA process, follow these steps:
    1. Delete the configuration for the old PIM (the PIM you are returning as part of the RMA process).
    2. Remove the old PIM, and return it as part of the RMA process.
    3. Insert the new PIM (the PIM you received as part of the RMA process).
    4. Reboot the vEdge 2000 router.
    5. Configure the interfaces for the new PIM.
  • On a vEdge 5000 router, you cannot enable TCP optimization by configuring the tcp-optimization-enabled command.

Software Caveats

The following are known behaviors of the software:

Cellular Interfaces

  • When configuring cellular attach-profile and data-profile on Cisco IOS XE routers running the XE SD-WAN software, you must use the default profile ID.
  • When configuring a cellular interface on a Cisco ISRv router running the XE SD-WAN software, profile changes are not supported.
  • The vEdge 100wm router United States certification allows operation only on non-DFS channels.
  • When you are configuring primary and last-resort cellular interfaces with high control hello interval and tolerance values, note the following caveats:
    • When you configure two interfaces, one as the primary interface and the other as the last-resort interface, and when you configure a high control hello interval or tolerance values on the last-resort interface (using the hello-interval and hello-tolerance commands, respectively, the OMP state indicates init-in-gr even though it shows that the control connections and BFD are both Up. This issue was resolved in Release 16.2.3. However, the following caveats exist:
      — You can configure only one interface with a high hello interval and tolerance value. This interface can be either the primary or the last-resort interface.
      — In certain cases, such as when you reboot the router or when you issue shutdown and no shutdown commands on the interfaces, the control connections might take longer than expected to establish. In this case, it is recommended that you issue the request port-hop command for the desired color. You can also choose to wait for the vEdge router to initiate an implicit port-hop operation. The request port-hop command or the implicit port hop initiates the control connection on a new port. When the new connection is established, the stale entry is flushed from the vSmart controllers.
    • If the primary interface is Up, as indicated by the presence of a control connection and a BFD session, and if you configure a last-resort interface with higher values of hello interval and tolerance than the primary interface, if you issue a shutdown command, followed by a no shutdown command on the last-resort interface, the last-resort interface comes up and continuously tries to establish control connections. Several minutes can elapse before the operational status of the last-resort interfaces changes to Down. If this situation occurs, it is recommended that you issue a request port-hop command for the desired color.
    • If you have configured a primary interface and a last-resort interface that has higher hello interval and tolerance values than the primary interface, and if the last-resort interface has control connections to two vSmart controllers, if you issue a shutdown command, followed by a no shutdown command on the last-resort interface, a control connection comes up within a reasonable amount of time with only one of the vSmart controllers. The control connection with the second vSmart controller might not come up until the timer value configured in the hello tolerance has passed. If this situation occurs, it is recommended that you issue a request port-hop command for the desired color.
  • When you activate the configuration on a router with cellular interfaces, the primary interfaces (that is, those interfaces not configured as circuits of last resort) and the circuit of last resort come up. In this process, all the interfaces begin the process of establishing control and BFD connections. When one or more of the primary interfaces establishes a TLOC connection, the circuit of last resort shuts itself down because it is not needed. During this shutdown process, the circuit of last resort triggers a BFD TLOC Down alarm and a Control TLOC Down alarm on the vEdge router. These two alarms are cleared only when all the primary interfaces lose their BFD connections to remote nodes and the circuit of last resort activates itself. This generation and clearing of alarms is expected behavior.
  • For cellular interface profile, the profile number can be 0 through 15. Profile number 16 is reserved, and you cannot modify it.

Configuration and Command-Line Interface

  • When you upgrade to Release 17.2 from any prior Viptela software release, the CLI history on the Viptela device is lost. The CLI history is the list of commands previously entered at the CLI prompt. You typically access the history using the up and down arrows on the kayboard or by typing Ctrl-P and Ctrl-N. When you upgrade from Release 17.2 to a later software release, the CLI history is maintained.
  • When you issue the request reset configuration command on a vEdge Cloud router, a vManage NMS, or a vSmart controller, the software pointer to the device's certificate might be cleared even though the certificate itself is not deleted. When the device reboots and comes back up, installation of a new certificate fails, because the certificate is already present. To recover from this situation, issue the request software reset command.

Control and BFD Connections

  • When a vBond orchestrator, vManage NMS, or vSmart controller goes down for any reason and the vEdge routers remain up, when the controller device comes back up, the connection between it and the vEdge router might shut down and restart, and in some cases the BFD sessions on the vEdge router might shut down and restart. This behavior occurs because of port hopping: When one device loses its control connection to another device, it port hops to another port in an attempt to reestablish the connection. For more information, see the Firewall Ports for Viptela Deployments article. Two examples illustrate when this might occur:
    • When a vBond orchestrator goes down for any reason, the vManage NMS might take down all connections to the vEdge routers. The sequence of events that occurs is as follows: When the vBond orchestrator crashes, the vManage NMS might lose or close all its control connections. The vManage NMS then port hops, to try to establish connections to the vSmart controllers on a different port. This port hopping on the vManage NMS shuts down and then restarts all its control connections, including those to the vEdge routers.
    • All control sessions on all vSmart controllers go down, and BFD sessions on the vEdge routers remain up. When any one of the vSmart controllers comes back up, the BFD sessions on the routers go down and then come back up because the vEdge routers have already port hopped to a different port in an attempt to reconnect to the vSmart controllers.
  • When a vEdge router running Release 16.2 or later is behind a symmetric NAT device, it can establish BFD sessions with remote vEdge routers only if the remote routers are running Release 16.2 or later. These routers cannot establish BFD sessions with a remote vEdge router that is running a software release earlier than Release 16.2.0.
  • When you add or remove an IPv4 address on a tunnel interface (TLOC) that already has an IPv6 address, or when you add or remove an IPv6 address on a TLOC that already has an IPv4 address, the control and data plane connections for that interface go down and then come back up.
  • Release 16.3 introduces a feature that allows you to configure the preferred tunnel interface to use to exchange traffic with the vManage NMS. In the vManage NMS, you configure this on cellular, Ethernet, and PPP Interface feature templates, in the vManage Connection Preference field under Tunnel Interface. In the CLI, you configure this with the vmanage-connection-preference command. The preference value can be from 0 through 8, with a lower number being more preferred. The default value is 5. If you set the preference value to 0, that tunnel interface is never used to exchange traffic with the vManage NMS, and it is never able to send or receive any overlay network control traffic.
    With this configuration option, there is one situation in which you can accidentally configure a device such that it loses all its control connections to all Viptela controller devices (the vManage NMSs and the vSmart controllers). If you create feature templates and then consolidate them into a device template for the first time, the NMS software checks whether each device has at least one tunnel interface. If not, a software error is displayed. However, when a device template is already attached to a device, if you modify one of its feature templates such that the connection preference on all tunnel interfaces is 0, when you update the device with the changes, no software check is performed, because only the configuration changes are pushed to the device, not the entire device template. As a result, these devices lose all their control connections. To avoid this issue, ensure that the vManage connection preference on at least one tunnel interface is set either to the default or to a non-0 preference value.

Interfaces

  • On virtual interfaces, such as IRB, loopback, and system interfaces, the duplex and speed attributes do not apply, and you cannot configure these properties on the interfaces.
  • When a vEdge router has two or more NAT interfaces, and hence two or more DIA connections to the internet, by default, data traffic is forwarding on the NAT interfaces using ECMP. To direct data traffic to a specific DIA interface, configure a centralized data policy on the vSmart controller that sets two actions—nat and local-tloc color. In the local-tloc color action, specify the color of the TLOC that connects to the desired DIA connection.
  • When configuring interfaces for an IOS XE router using one of the VPN Interface feature configuration templates, you must spell out the interface names completely. For example, you must type GigabitEthernet0/0/0. Also, you must define all the interfaces in the router even if you are not using them so that they are configured in the shutdown state and so that all default values for them are configured.

IPv6

  • You can configure IPv6 only on physical interfaces (ge and eth interfaces), loopback interfaces (loopback0, loopback1, and so on), and on subinterfaces (such as ge0/1.1).
  • For IPv6 WAN interfaces in VPN 0, you cannot configure more than two TLOCs on the vEdge router. If you configure more than two, control connections between the router and the Viptela controllers might not come up.
  • IPv6 transport is supported over IPsec encapsulation. GRE encapsulation is not supported.
  • You cannot configure NAT and TLOC extensions on IPv6 interfaces.
  • DHCPv6 returns only an IPv6 address. No default information is accepted. IPv6 router solicitation and router advertisement messages are not processed.

IRB

  • On integrated routing and bridging (IRB) interfaces, you cannot configure autonegotiation.

NAT

  • When you reboot a vSmart controller, the BFD sessions for all symmetric NAT devices go down and come back up. This is expected behavior.

Routing Protocols

  • When a vEdge router transport interface is using an old IPv6 SLAAC address for control connections or BFD sessions, or both, the IP address used for control connections and BFD might become out of sync with the actual IPv6 address. This situation can happen when the IPv6 address that SLAAC advertises from the gateway router changes suddenly and the old IPv6 address has not first been invalidated. As a workaround, if the router has no mechanism to invalidate older prefixes when the IPv6 prefix changes, first remove the router-advertisement configuration on the default gateway router and then change the IPv6 address. To resolve this problem when it occurs on a vEdge router, shut down the interface and then restart it; that is, issue a shutdown command, followed by a no shutdown command.
  • When you configure OSPF using a vManage NMS device configuration template, the configuration of an NSSA area or a stub area and the configuration of an area range are not pushed to the router when you attach the device configuration template to the router. As a workaround, configure these parameters in CLI mode on the router, from the vManage Tools ► SSH Terminal screen, using the OSPF area and range configuration commands.

Security

  • It is recommended that you use IKE Version 2 only with Palo Alto Networks and Ubuntu strongSwan systems. Viptela has not tested IKE Version 2 with other systems.

SNMP

  • When you configure an SNMP trap target address, you must use an IPv4 address.
  • The Viptela interface MIB supports both 32-bit and 64-bit counters, and by default sends 64-bit counters. If you are using an SNMP monitoring tool that does not recognize 64-bit counters, configure it to read 32-bit MIB counters.

T1/E1

  • If you wish to change the card and controller type on the device, you must first remove the previously configured card and controller and reboot the device.
  • You cannot configure rollback or load override features on a multilink interface.
  • PPP multilink QoS is currently not supported in the VPN Interface Multilink template.
  • PPP multilink NAT is currently not supported in the VPN Interface Multilink template.
  • For a vEdge Cloud VM instance on the KVM hypervisor, for Viptela Releases 16.2.2 and later, it is recommended that you use virtio interfaces. For software versions earlier than Release 16.2.2, if you are using the Ubuntu 14.04 or 16.04 LTS operating system, you can use IDE, virtio, or virtio-scsi interfaces.

vManage NMS

  • On a Viptela device that is being managed by a vManage NMS system, if you edit the device's configuration from the CLI, when you issue the commit command, you are prompted to confirm the commit operation. For example:
    vEdge(config-banner)# commit
    The following warnings were generated:
      'system is-vmanaged': This device is being managed by the vManage. Any configuration changes to this device will be overwritten by the vManage.
    Proceed? [yes,no]

    You must enter either yes or no in response to this prompt.
    During the period of time between when you type commit and when you type either yes or no, the device's configuration database is locked. When the configuration database on a device is locked, the vManage NMS is not able to push a configuration to the device, and from the vManage NMS, you are not able to switch the device to CLI mode.
  • The members of a vManage cluster rely on timestamps to synchronize data and to track device uptime. For this time-dependent data to remain accurate, do not change the clock time on any one of the vManage servers of the cluster after you create the cluster.
  • When you use the vManage Maintenance ► Software Upgrade screen to set the default software version for a network device, that device must be running Release 16.1 or later at the time you set the default software version. If the network device is running Release 15.4 or earlier, use the CLI request software set-default command to set the default software version for that device.

  • When you are using a vManage cluster, when you are bringing up new vManage NMS in the cluster, use an existing vManage NMS to install the certificate on the new vManage NMS.

  • In vManage feature configuration templates, for the passwords listed below, you cannot enter a cleartext password that starts with $4 or $8. You can, however, use such passwords when you are configuring from the CLI.

    • Neighbor password, in the BGP feature configuration template

    • User password, in the Cellular Profile feature configuration template

    • Authentication type password and privacy type password, in the SNMP feature configuration template

    • RADIUS secret key and TACACS+ secret key, in the System feature configuration template

    • IEEE 802.1X secret key, in the VPN Interface Ethernet feature configuration template

    • IPsec IKE authentication preshared key, in the VPN Interface IPsec feature configuration template

    • CHAP and PAP passwords, in the VPN Interface PPP Ethernet feature configuration template

    • Wireless LAN WPA key, in the WiFi SSID feature configuration template

  • PPP CHAP is currently not supported in the VPN Interface Multilink template.
  • PPP multilink fragmentation is currently not supported in the VPN Interface Multilink template.
  • If a serial interface is bundled into a multilink interface, you cannot remove it from the vManage NMS.
  • Once you attach the VPN Interface Multilink template to a device, you cannot detach it from the device.

Outstanding Issues

The following are outstanding issues in XE-SDWAN Software Release 16.9.1 and SD-WAN Software Release 18.3. The CSC number following each issue is the bug number in the Cisco Defect Tracking System. The VIP number following each issue is the bug number in the Viptela bug-tracking database.

Cellular Interfaces

  • When you configure cellular interfaces on an IOS XE router, the cellular profile may not be written to the modem. [CSCvk08395]
  • On an IOS XE router, you cannot delete the VDSL controller configuration. [CSCvk27232]
  • On an ISRv router, you cannot modify the cellular controller configuration. [CSCvk27736]
  • On an IOS XE router, when a cellular interface is configured as a last-resort interface, the operational state of the interface might be Up. [CSCvk38707]
  • If you configure IPv6 on a cellular interface, the control connections might go down and come back up continuously. [VIP-21970]

Configuration and Command-Line Interface

  • On an IOS XE router, the file generated by the request admin-tech command might not include DSL-related information or ATM/dialer-related information. [CSCvj43195, CSCvj54679]
  • On an IOS XE router, when you push a configuration template in which the interface to the vManage NMS is configured as down, it might take 15 minutes to roll back the configuration instead of the usual 5 minutes. [CSCvj88473]
  • On an IOS XE router, when you issue the show platform software trace command from the CLI, the router might reboot unexpectedly. As a workaround, use the request admin-tech command to collect the trace information. [CSCvj90293]
  • On an IOS XE router, EEM-related configurations on Confd are not supported. [CSCvj95656]
  • On an IOS XE router, when you configure a centralized data policy with an app-list match condition, the policy might not work as expected. [CSCvk27018]
  • On an ASR 1002-HX router, after you reload the device, NAT translation might no longer work. As a workaround, either shut down and the restart the NAT interface, or remove and re-appply the source list. [CSCvk33230]
  • When you issue the show vrrp interfaces command from the router's CLI, the CLI might not recognize the command and might show a "syntax error: unknown argument" error message. [VIP-23918]

  • If a physical interface is part of a bridge, you cannot adjust the MTU on the interface. As a result, the 802.1x interface's MTU has to be lowered to 1496. If the interface needs to also run OSPF, this MTU size can cause an MTU mismatch with other interfaces that have an MTU of 1500. [VIP-26759]

  • When two routes exist to the same neighbor, if you specify a single IP address in the show ip routes command, the command might return only one of the routes, but if you specify an IPv4 prefix and prefix length, the command returns both routes. [VIP-32736]
  • With the ping source ip-address command, if you type it as ping so ip-address, the CLI does not autocomplete so and the command fails. You must type out the keyword source. [VIP-36087]
  • When you use the show ip route command to query a route that is not present in the route table, the command might return no output or no failure message. [VIP-36725]
  • When you configure a hostname that includes a period (.), only the portion of the hostname before the period is displayed. As a workaround, use an underscore (_) or a hyphen (-). [VIP-38369]
  • The show omp routes command output might display the incorrect tag for OMP routes. [VIP-39722]
  • When you attempt to activate a vEdge cloud router on which the organization name is not configured, the router is not activated and no error message is displayed. [VIP-40503]
  • If a vEdge router exhausts all its NAT entries, old entries do not get cleared and new NAT entries are not created. [VIP-41734]
  • On a vEdge router, if you configure a NAT interface and if the private-to-public port mapping is different for the router's IP address of the vEdge router, the NAT might not work as expected. [VIP-41756]

Forwarding

  • You cannot configure an ISRv router from a CD-ROM device. As a workaround, configure the router from the /bootflash or /usbflash0 device. [CSCvk27394]
  • On an IOS XE router, VPN 0 traffic might not be NATed over interfaces configured as TLOC extensions. [CSCvk34856]

  • For IEEE 802.1X, you cannot configure a RADIUS server for MAC authentication bypass (MAB). [VIP-18492]
  • In application-aware routing policy, the salesforce_chatter, oracle_rac, and google_photos applications might not be classified properly. [VIP-21866]
  • When you switch data traffic from one tunnel to another (for example, from a biz-ethernet to an lte tunnel), a small amount of traffic might be lost. [VIP-27992]
  • For a source and destination NAT, return traffic might not be able to reach the VPN that originates the session. [VIP-31299]
  • When you configure inbound and outbound port mirroring on the same interface, traffic might be mirrored only in one direction. [VIP-33247]
  • When you have a localized data policy (ACL) that mirrors traffic on an interface in both directions, if you change the IP address of the interface and the mirror destination but do not remove the ACL, the outbound mirroring continues to work but the inbound mirroring stops working. If you then remove and reapply, the ACL, the mirroring again works in both directions. [VIP-33275]
  • If you disable deep packet inspection (DPI) on a vEdge router, traffic directed towards queue 0 (LLQ) might become bursty or might be dropped. [VIP-34211]
  • When you configure a cellular interface as a last-resort interface, the cellular interface might remain up at all times. [VIP-34495]
  • Routes might be installed in the routing table with the incorrect color. [VIP-35088]
  • Traffic might be blackholed because of stale BFD sessions. This happens in a scenario when there are two vEdge routers at a site, both configured with TLOC extension between them, and the circuit that they are connected to goes down. One router clears all its BFD sessions, but the second one does not, so all traffic is sent to the uncleared BFD sessions and is blackholed. [VIP-35113]
  • On a vBond orchestrator, if you configure allow-service netconf, the vBond orchestrator does not open TCP port 830 and thus cannot connect to the vManage NMS. As a workaround, configure allow-service all. [VIP-35916]
  • The vManage DPI screen might display a DIA graph for a vEdge router on which local internet exit is not configured. [VIP-38987]

  • A vEdge router might crash with the error message, "FTMD-3-ERRO-1000011: FP Core 1 Died. Core file recorded at /var/crash/core.fp1.5310". [VIP-39318]

Interfaces

  • On an IOS XE router, when you configure a tunnel interface to be an interface of last resort, that interface's operational status might not be set to down state even when other tunnel interfaces are up. [CSCvk19310]
  • On an IOS XE router, the VLAN interface IP address might be advertised even when no physical interface is associated with it. [CSCvk34720]
  • When you reboot an ASR1001-X router, the operational status of the interface that has an SFP plugged might show an as down. [CSCvj94133]
  • In vManage NMS, removing a DSL configuration from a router might fail with the errors "Failed to process device request" and "inconsistent value: Device refused one or more commands". [CSCvk29514]
  • On a vEdge router that has two TLOCs, one on a loopback interface and the second on a physical interface, when the physical interface goes down, the loopback interface might not be able to forward traffic. [VIP-34646]
  • You might not be able to configure the Cloud Onramp VPC even when vEdge routers are present. [VIP-34655]
  • On a vEdge 100b router running Release 17.2.6, when you enable transport interface tracking on an interface, if you bring the interface down, the tracker might fail and cause the router to crash. [VIP-40006]

Policy

  • On an IOS XE router, when you configure a centralized data policy with no sequences and with the default action (drop), the from-service or from-tunnel apply options might not work. [CSCvh94044]
  • For zone-based firewalls, you can configure a VPN to be in only one zone. [CSCvi97773]
  • When you change the name of a counter in a centralized policy, the counter name might not be updated when the vSmart controller pushes the policy to an IOS XE router. [CSCvj60148]
  • You cannot match ICMP in a policy that you associate with the source and destination zones in a zone pair​, because ICMP is not a transport layer protocol and zone pair policies match only TCP protocols. [CSCvk03248]
  • The Policy Zone Pair Sessions real-time command in the vManage NMS might not work. [CSCvk36514]
  • The zone pair statistics​ displayed on the vManage NMS might not be the same as the statistics displayed on the router itself. [CSCvk86517]
  • You can no longer configure a QoS map (with the vpn interface qos-map command) on a VLAN interface (also called a subinterface). You also cannot configure the aggregate traffic rate on a VLAN interface (with the vpn interface shaping-rate command). [VIP-22820]
  • A centralized policy that is pushed from the vSmart controller to the vEdge routers might not be applied on the routers. [VIP-27046]
  • In vManage NMS, when you use the policy configuration wizard to create policies for a mesh topology, you might need to create an additional policy using a CLI template for the mesh policy to work. This situation is known to occur in a network that has two regions, where each region is mesh that is a subset of the entire network, where each region has its own data center, and where the branch vEdge routers in one region communicate with branch routers in the other region through the data centers. We will call these Region 1 and Region 2. Assume that Region 1 has a control policy that advertises its TLOCs to the data center in Region 2, and Region 2 has a control policy that prevents the spokes and data center in Region 2 from advertising TLOCs to the spokes in Region 1. The result is that the data center in Region 2 repeatedly attempts to form control tunnels to the data center in Region 1, but these attempts fail. As a workaround, you must a policy using a CLI template that allows the data center in Region 2 to exchange TLOCs with the data center in Region 1 and then attach that policy to the vEdge routers. [VIP-29933]
  • In the vManage Centralized Policy UI Builder, the Membership has no options to accept or reject and no way to change the default action. These options are all available in CLI and need to be added to the UI builder for the same capabilities. [VIP-38730]

  • An implicit or a configured ACL might not work on loopback interfaces. [VIP-38731]

Routing Protocols

  • You two IPv6 interfaces on a vEdge router are active at the same time, basic packet forwarding (such as ping) might fail. Only one interface works at a time, and the router switches back and- orth between the two interfaces. [VIP-37810]
  • When you configure VPN-specific OMP route advertisement parameters to two VPNs on a vEdge router, they might not be applied properly in the VPNs. [VIP-37860]
  • In the BGP feature template, the BGP neighbor route policy variable name is displayed as the default name (bgp_neighbor_policer_out_pol_name) rather than the name you enter. However, the name you enter does show up when you are attaching the template to the device. [VIP-37988]

  • The show omp tlocs advertised command might not properly filter TLOC-advertised routes. [VIP-39400]
  • On a vEdge router, the OSPF routes are automatically redistributed to OMP. [VIP-40090]
  • When you configure BGP to aggregate routes, OMP might advertise routes that do not match one of the prefixes. [VIP-40105]

Security

  • On an IOS XE router, when you change the OSPF password, the commit might fail. [CSCvj92237]
  • The Viptela process (vdaemon) might crash when booting up an IOS XE router. [CSCvj98370]
  • When you issue the request reset configuration command on a vEdge Cloud router, a vManage NMS, or a vSmart controller, the software pointer to the device's certificate might be cleared even though the certificate itself is not deleted. When the device reboots and comes back up, installation of a new certificate fails, because the certificate is already present. To recover from this situation, issue the request software reset command. [VIP-23825]
  • In an overlay network with three vSmart controllers, if a controller group list configured on a 100 vEdge router contains two vSmart controllers, the maximum number of controllers that the router can connect to is set to two, and the maximum number of OMP sessions on the router is set to two, 50 routers connect to each of two vSmart controllers. If you bring these two controllers down, all 100 connections then move to the third vSmart controller. However, if you then bring up one of the other vSmart controllers, 50 connections move to that controller, but the third controller might still have 100 connections. [VIP-27955]
  • When a certificate for controllers is about to expire, no syslog message is generated. [VIP-28960]
  • When you specify a DNS destination for IPsec on a tunnel in VPN 0, the Forwarding Table Management process (ftmd), the OMP process (ompd), or the IKE procee (iked) might crash. [VIP-38888]
  • A vEdge 100 router might reboot regularly, with the message "Software initiated - Daemon 'vdaemon' failed. CPU-reported reboot: Warm". [VIP-39440]

SNMP

  • When traffic exceeds 85% of the bandwidth configured on a transport interface, SNMP traps might not get triggered. [VIP-33435]
  • When you poll the VIPTELA-OPER-VPN MIB, interface descriptions are limited to 32 characters. [VIP-35787]

System

  • On an IOS XE router, PnP might configure a static IP address instead of a DHCP address during the PnP workflow. [CSCvk16663]
  • If you invalidate an ASR 1001-X or ISRv router from vManage NMS, the request platform software sdwan config reset command might give a permission error. [CSCvk21130]
  • vBond orchestrators might report a large number of control-connection-auth-fail events. [VIP-22976]
  • The output of the show interface sfp detail command might show that the copper minimum length, instead of the maximum length, is 100m. [VIP-28673]
  • On vEdge routers, when you issue an nping command for IPv6, the command might fail, and a core file might be created on the router. From vManage NMS, you issue this command from the Monitor ► Network ► Troubleshooting ► Ping pane. From the CLI, you use the tools nping command, specifying options "--ipv6". [VIP-31924]
  • The vdebug log file might contain no entries. [VIP-33662]
  • A vSmart controller might crash and create the core file /rootfs.rw/var/crash/core.vtracker.vSmart, indicating an issue with the vtracker process, which pings the vBond orchestrator every second. [VIP-33719]
  • The TCP optimization process might consume a large amount of CPU even though TCP optimization is not configured. [VIP-36675]
  • Log file messages might not include the correct date in the timestamp. [VIP-37086]
  • When you change the negotiated interface speed on a vEdge router, the buffer allocation also changes. [VIP-37238]
  • The gzip process on a router might consume a lot of CPU. [VIP-39228]

vEdge Hardware

  • On a vEdge 100m router, after you execute the request software reset command, the router might reboot continuously. [VIP-24149]

  • On a vEdge 100b, when you change the IP address on an interface, that IP address might not be detached from the interface. [VIP-35047]

vManage NMS

  • On an IOS XE router, pushing a configuration template might fail with the error "failed to publish task on message bus". As a workaround, restart all the NMS servers from the vManage NMS. [CSCvk23051]
  • On an IOS XE router, you might not be able to delete a dialer interface in no shut state from the vManage NMS. [CSCvk27129]
  • If you try to configure a vEdge router using vManage configuration templates, you might see errors related to lock-denied problems. As a workaround, reboot the router. [VIP-23826]
  • When you use the vManage NMS and the CLI show system status command, the reboot reason is incorrect; it is shown as unknown. The /var/log/tmplog/vdebug logs shows that the system reboot happened because of a user-initiated upgrade to Release 17.1.3. [VIP-31222]
  • In the vManage AAA feature template, you might not be able to enter the RADIUS secret key even though you can enter that same key in the CLI. [VIP-31856]
  • When you push a policy that contains an error to the vSmart controller, the error message might not correctly indicated the cause of the error. [VIP-32253]
  • You might not be able to reset an interface on an IOS XE router from the vManage NMS. [VIP-34418]
  • You might not be able to push configuration templates to vEdge routers. [VIP-34886]
  • When you change the names of the route policies in a localized policy, the modified policy might not work as expected. [VIP-35026]
  • After a vManage NMS silently reboots, it might be out of sync with the vManage cluster. [VIP-35891]
  • When a vBond orchestrator is unreachable or has wrong credentials configured, pushing a vEdge list to it fails with the message “File /home/user/vedge_serial_numbers must be in home directory”, which does not provide any useful information to the user to understand what is wrong. [VIP-36285]
  • The default VPN 512 management feature template is named "Transport VPN", which is confusing because VPN 0 is the transport VPN. [VIP-36771]
  • If NMS services are down on one of the servers in a vManage cluster, you might not be able to perform an CLI operations from the vManage NMS. [VIP-37672]
  • In a vManage cluster with two servers, if both servers go down, you might need to manually restart the vManage services to return the vManage servers to an operational state. To do this, issue the request nms configuration-db restart command from the vManage server. One way to determine whether you need to restart the services is to check the /var/log/nms/debug.log file on the vManage server for a message indicating that neo4j needs to be restarted. [VIP-38228]
  • If you reboot one of vManage servers in a cluster while the vManage NMS is downloading a software image to a vEdge router, the cluster might report server errors and might stop operating properly. [VIP-38556]
  • In Forwarding Class/QoS in the Localized Policy wizard, if you create a class map, assign a queue to that class map, successfully add the queue, and then delete the class from the class map list, the Forwarding Class column might be empty instead of displaying the class name. [VIP-38690]

  • If you are using ZTP or attaching a template with bridge configuration to a new vEdge router, pushing the device configuration template to the router might fail because of a bridge configuration. As a workaround, remove the bridge configuration from feature template, apply the IRB configuration, and then apply the bridge configuration. [VIP-39525]

  • The vManage GUI might not start, and the vmanage-server.log file might contain a lot of exceptions. [VIP-39644]

  • When you use VLAN tagged interfaces for transport interfaces, the interface throughput might drop. [VIP-39647]

  • When you bring up a router from the vManage NMS, duplicate entries for these devices might show up in the Configuration ► Device and Configuration ► Certificates screens. [VIP-39692]

  • You might not be able to change the AWS instance from C3 to C4. [VIP-40092]
  • On the vManage Monitor ► Alarms screen, the OMP site down alarm might not clear after the OMP connection is restored. [VIP-40200]
  • The output of the show bridge interface command might not list all the configured bridges. [VIP-40299]
  • When you temporarily disconnect a vEdge router from the network, data stream settings might go out of sync and vManage NMS might report an error. If this happens, disable and then re-enable the data stream. [VIP-41369]
  • Upgrading a vEdge router using ZTP might fail for routers that use MIPS images. [VIP-41621]
  • If ZTP is enabled on a vManage NMS running Release 18.2, you must enable ZTP again after you upgrade the vManage NMS to Release 18.3. [VIP-41637]
  • When ZTP Software Install task starts while a Software Install task is in progress, the installation task might fail. [VIP-41873]

Fixed Issues

Issues Fixed in Release 18.3.0

The following issues have been fixed in Viptela Software Release 18.3.0. The number following each issue is the bug number in the Viptela bug-tracking database.

Configuration and Command-Line Interface

  • A color that you configure using a vManage configuration template might not be applied correctly on a vEdge router. [VIP-38735: This issue has been resolved.]

DHCP

  • When the software reads the DHCP lease file, the read might fail, resulting in a vdhcpsd core. [VIP-39037: This issue has been resolved.]

Forwarding

  • If the vEdge routers in your overlay network are running Release 17.2, you cannot add routers to the network that are running Release 15.4. [VIP-35084: This issue has been resolved.]
  • On a vEdge 100m router, the Forwarding Table Management process (ftmd) might crash. [VIP-39984: This issue has been resolved.]

Interfaces

  • Starting with Release 18.3.0, VRRP on vEdge routers is RFC compliant with respect to virtual MAC addresses. There is a guaranteed support of 24 VRRP groups per vEdge router. [VIP-33722: This issue has been resolved.]
  • When you configure interface tracking on two interfaces in a vEdge router, the router might crash. [VIP-38829: This issue has been resolved.]

Policy

  • On x86 vEdge routers (Cloud vEdge routers and vEdge 5000 routers), when you configure QoS schedulers, any traffic that queued in a queue to which no bandwidth or buffer is assigned will be dropped. [VIP-38008: This issue has been resolved.]

Routing Protocols

  • When you are upgrading vEdge routers to Release 16.2.12, the BGP process (bgpd) might crash during the reboot process, when the router is shutting down. [VIP-29523: This issue has been resolved.]

Security

  • The Viptela software includes a version of OpenSSH that is affected by the vulnerabilities identified by the following Common Vulnerability and Exposures (CVE) IDs: CVE-2016-10009 and CVE-2016-10012. [VIP-34808: This issue has been resolved.]

vEdge Hardware

  • In a vEdge 5000 router, if you remove and replace an SFP without powering off the router, the router is unable to detect the new SFP module details. For example, the show hardware inventory command will not list the SFP module. However, the ports on the SFP still connect and work as expected. [VIP-37562: This issue has been resolved.]
  • A vEdge 5000 router might not be able to start because of issues with its internal verification hardware. [VIP-38219: This issue has been resolved.]

vManage NMS

  • In the vManage policy builder, you can configure a site list name that is longer that is allowed on the vSmart controller. When you attempt to activate the policy, an error occurs on the vSmart controller, [VIP-37859: This issue has been resolved.]
  • The vManage NMS might occasionally indicate that the software upgrade on a vEdge router has succeeded even though it has failed. This has been observed only rarely. [VIP-39004, VIP-39041: This issue has been resolved.]
  • The vManage interface feature configuration templates do not have drop-downs for selecting interface speed and duplex settings. [VIP-37973: This issue has been resolved.]
  • After a CSR request is sent to Symantec but before the certificate has been approved, the vManage request to retrieve the certificate might die, and so the vManage NMS might not be able to retrieve the certificate even after it has been approved. [VIP-38093: This issue has been resolved.]

  • When a localized policy that includes a policer is attached to a vEdge router and is active on that device, you might not be able to edit the policer in the vManage policy wizard. [VIP-39294: This issue has been resolved.]

  • The vManage dashboard might show an incorrect number of vBond orchestrators. [VIP-40033: This issue has been resolved.]
  • When you issue the show system buffer-pool-status command, the following error might occur: "Error: application communication failure". [VIP-40073: This issue has been resolved.]
  • When you create a new vManage VM instance and are formatting the third partition, there might be no indication that the formatting is progressing. [VIP-40254: This issue has been resolved.]
  • After you reboot a large number of routers, the vManage cluster performance might degrade. [VIP-40330: This issue has been resolved.]
  • Staging routers might take a long time if they are using the same site ID. [VIP-41554, VIP-41558: These issues have been resolved.]

 

YANG Files for Netconf and Enterprise MIB Files

Netconf uses YANG files to install, manipulate, and delete device configurations, and Viptela supports a number of enterprise MIBs. Both are provided in a single tar file. Click the filename below to download the file.

Using the Product Documentation

The SD-WAN product documentation is organized into seven modules:

Module Description
Getting Started Release notes for Viptela software releases, information on bringing up the Viptela overlay network for the first time, quick starts for vEdge routers, software download and installation, and an overview of the Viptela solution.
vEdge Routers

How to install, maintain, and troubleshoot vEdge routers and their components. Provides hardware server recommendations for the controller devices—vManage NMS, vSmart controller, and vBond orchestrator servers.

Software Features

Overview and configuration information for software features, organized by software release.

vManage How-Tos Short step-by-step articles on how to configure, monitor, maintain, and troubleshoot Viptela devices using the vManage NMS.
Command Reference

Reference pages for CLI commands used to configure, monitor, and manage the Viptela devices. Includes reference pages for Viptela software REST API, a programmatic interface for controlling, configuring, and monitoring the Viptela devices in an overlay network.

vManage Help Help pages for the vManage screens. These pages are also accessible from the vManage GUI.

Tips

  • To create a PDF of an article or a guide, click the PDF icon located at the top of the left navigation bar.
  • To find information related to an article, see the Additional Information section at the end of each article.
  • To help us improve the documentation, click the Feedback button located in the upper right corner of each article page and submit your comments.

Using the Search Engine

  • To search for information in the documentation, use the TechLibrary Search box located at the top of each page.
  • On the Help results page, you can narrow down your search by selecting the appropriate documentation module at the top of the page. If, for example, you are searching for power supply information for your vEdge router model, select the Hardware module and then select your vEdge router model.
  • When a search returns multiple entries with the same title, check the URL to select the article for your hardware platform or software release.
  • When the search string is a phrase, the search engine prioritizes the individual words in a phrase before returning results for the entire phrase. For example, the search phrase full-cone NAT places links to "NAT" at the top of the search results. If such a search request does not return relevant results, enclose the entire search string in quotation marks (here, for example, "full-cone NAT").

Issues

  • The maximum PDF page limit is 50 pages.
  • It is recommended that you use the Chrome browser when reading the production documentation. Some of the page elements, such as the PDF icon, might not display properly in Safari.
  • The screenshots for the vManage NMS screens that are included in the vManage help files and other documentation articles might sometimes not match the vManage NMS software screens. We apologize for the inconvenience.

Requesting Technical Support

To request technical support, send email to support@viptela.com.

To provide documentation feedback or comments, send email to docs@viptela.com.

Revision History

Revision 1—IOS XE SD-WAN Release 16.9.1 and SD-WAN Release 18.3, July 17, 2018

  • Was this article helpful?